Ç¥ÁØÈ­ Âü¿©¾È³»

TTAÀÇ Ç¥ÁØÇöȲ

Ȩ > Ç¥ÁØÈ­ °³¿ä > TTAÀÇ Ç¥ÁØÇöȲ

Ç¥ÁعøÈ£ TTAE.IT-G.808.3 ±¸Ç¥ÁعøÈ£
Á¦°³Á¤ÀÏ 2021-12-08 ÃÑÆäÀÌÁö 43
ÇѱÛÇ¥Áظí ÀÏ¹Ý °øÀ¯ ¸Þ½Ã º¸È£ Àýü
¿µ¹®Ç¥Áظí Generic protection switching – Shared mesh protection
Çѱ۳»¿ë¿ä¾à ÀÌ Ç¥ÁØÀº Á¦¾î Æò¸é¿¡ ÀÇÁ¸ÇÏÁö ¾Ê´Â ¿¬°á ÁöÇâ °èÃþ ¸Á¿¡¼­ °øÀ¯ ¸Þ½Ã º¸È£ÀÇ ÀϹÝÀûÀÎ ¾ç»ó¿¡ ´ëÇÑ °³¿ä¸¦ ±â¼úÇÏ°í ÀÖ´Ù. °øÀ¯ ¸Þ½Ã º¸È£´Â ³×Æ®¿öÅ©¿¡¼­ Çϳª ÀÌ»óÀÇ Àå¾Ö¿¡ ´ëÇÑ º¸È£¸¦ À§ÇØ ¸Þ½Ã ³×Æ®¿öÅ©¿¡¼­ ÀÚ¿øÀ» °øÀ¯ÇÏ´Â ¹æ¹ýÀ» Á¦°øÇÑ´Ù. ÀÌ Ç¥ÁØ¿¡¼­ Á¤ÀÇµÈ ¸ÞÄ¿´ÏÁòÀº º¸È£ ÀÚ¿øÀ» È¿À²ÀûÀ¸·Î ÀÌ¿ëÇϱâ À§ÇÑ ¸Þ½Ã ³×Æ®¿öÅ© ±¸Á¶¿¡ Àû¿ëµÇ¸ç, ¸Á Àå¾Ö ½Ã Æ®·¡ÇÈ º¹±¸ ¼Óµµ¸¦ ÃÖ´ëÈ­Çϱâ À§ÇØ »çÀü¿¡ °è»êµÇ°í ÇÒ´çµÈ ÀÚ¿øÀ» ÀÌ¿ëÇÏ¿© °æ·Î ±â¹ÝÀ¸·Î º¸È£ÇÏ´Â Á¢±Ù¹ýÀ» Ư¡À¸·Î ÇÑ´Ù.
¿µ¹®³»¿ë¿ä¾à The standard describes an overview of generic aspects of a shared mesh protection (SMP) mechanism for connection-oriented layer networks that does not depend upon the presence of a control plane. SMP provides a method for sharing resources in the mesh network for protection against one or more failures in the network. This mechanism is targeted for mesh network architectures, which offer further efficiencies in protection resource utilization. The primary characteristics of this path-based protection approach involve usage of pre-computation and pre-allocation of resources to maximize speed of recovery.
±¹Á¦Ç¥ÁØ ITU-T G.808.3
°ü·ÃÆÄÀÏ TTAE.IT-G.808.3.pdf TTAE.IT-G.808.3.pdf            

ÀÌÀü
Ŭ¶ó¿ìµå ÄÄÇ»Æà - ¸ÖƼ Ŭ¶ó¿ìµå¸¦ À§ÇÑ Å¬¶ó¿ìµå ¼­ºñ½º ÆÄÆ®³ÊÀÇ ±â´É ¿ä±¸»çÇ×
´ÙÀ½
¾çÀÚÅ° ºÐ¹è¸Á°ú º¸¾È ½ºÅ丮Áö¸ÁÀÇ ÅëÇÕÀ» À§ÇÑ ÇÁ·¹ÀÓ¿öÅ©