ÀÚ·á°Ë»ö-Ç¥ÁØ

Ȩ > ÀڷḶ´ç > ÀÚ·á°Ë»ö > Ç¥ÁØ

ÀÚ·á °Ë»ö°á°ú

°Ë»öÆäÀÌÁö·Î
Ç¥ÁØÁ¾·ù Á¤º¸Åë½Å´ÜüǥÁØ(TTAS)
Ç¥ÁعøÈ£ TTAK.IT-K.84 ±¸ Ç¥ÁعøÈ£
Á¦°³Á¤ÀÏ 2017-12-13 ÃÑ ÆäÀÌÁö 38
ÇÑ±Û Ç¥ÁØ¸í ºñÀǵµ¼º ÀüÀÚÆÄ ¹æÃâÀ» ÅëÇÑ Á¤º¸ ´©¼³ ½ÃÇè¹æ¹ý ¹× Áöħ
¿µ¹® Ç¥Áظí Test methods and guide against information leaks through unintentional EM emissions
ÇÑ±Û ³»¿ë¿ä¾à º» Ç¥ÁØÀº Á¤º¸Åë½Å¼¾ÅÍ ³» ÀüÀÚÆÄ ¹æ»ç º¸È£(EMSEC)¿Í °ü·ÃµÈ À§Çù ¹× ±â¹Ð¼º, ±×¸®°í º¸È£ À§Çù¿¡ ´ëÇÑ ¿ÏÈ­ ¹æ¹ý¿¡ ´ëÇÑ µÎ °¡Áö Á¢±Ù ¹æ¹ýÀ» ¼³¸íÇÑ´Ù. ù ¹ø° Á¢±Ù ¹æ¹ýÀº ±â±â¿¡ ´ëÇÑ ¹æÃ⠿䱸»çÇ×À» Æ÷ÇÔÇÏ°í, µÎ ¹ø° Á¢±Ù ¹æ¹ýÀº ITU-T K.48 ¹× KN/CISPR 22¿Í °°Àº ±âÁ¸ ÀüÀÚÆÄ ÀûÇÕ¼º ¹æÃâ Ç¥ÁØÀ» »ç¿ëÇÏ¿© °Ë»çÇÑ ±â±â°¡ ÇöÀå¿¡ ¼³Ä¡µÉ ¶§ ÇöÀå¿¡ ´ëÇÑ Â÷Æó ¿ä°ÇÀ» Æ÷ÇÔÇÑ´Ù.
¿µ¹® ³»¿ë¿ä¾à The standard describes threats and confidentiality related to EMSEC in telecommunication center, and two approaches to mitigation methods. The first approach involves emission requirements for equipment and the second involves shielding requirements for sites, when equipment that is examined with existing EMC emission standards such as ITU-T K.48 and KN/CISPR 22 is installed at a site.
°ü·Ã IPR È®¾à¼­ Á¢¼öµÈ IPR È®¾à¼­ ¾øÀ½
°ü·ÃÆÄÀÏ    TTAK.IT-K.84.pdf TTAK.IT-K.84.pdf
Ç¥ÁØÀÌ·Â
Ç¥Áظí Ç¥ÁعøÈ£ Á¦°³Á¤ÀÏ ±¸ºÐ À¯È¿
¿©ºÎ
IPR
È®¾à¼­
ÆÄÀÏ
ºñÀǵµ¼º ÀüÀÚÆÄ ¹æÃâÀ» ÅëÇÑ Á¤º¸ ´©¼³ ½ÃÇè¹æ¹ý ¹× Áöħ TTAK.IT-K.84 2017-12-13 Á¦Á¤ À¯È¿ ¾øÀ½ TTAK.IT-K.84.pdf