ÇѱÛÇ¥ÁØ¸í ¹æ¼Û Åë½Å ¼³ºñÀÇ ³»Áø ½ÃÇè ¹æ¹ý
¿µ¹®Ç¥Áظí Seismic Test Method for Telecommunication Facilities
Çѱ۳»¿ë¿ä¾à ÀÌ Ç¥ÁØ¿¡¼­´Â ¸ÕÀú ¹æ¼Û Åë½Å ¼³ºñ Áß ÁöÁø ´ëÃ¥À» À§ÇÏ¿© ³»Áø ¼³°è¸¦ Àû¿ëÇÏ°í ½ÃÇèÇÏ
¿©¾ß ÇÒ ´ë»ó ¼³ºñ¸¦ ºÐ·ùÇÏ°í ÀÖ´Ù. ³»Áø ¼³°è¿¡ ´ëÇÑ ÀûÇÕ¼ºÀ» ½ÃÇèÇÏ´Â ¹æ¹ýÀÇ ÇÙ½É ±â¼ú
ÀÎ ¿ä±¸ ÀÀ´ä ½ºÆåÆ®·³°ú ½ÃÇè ÀÀ´ä ½ºÆåÆ®·³ÀÇ ±Ô°ÝÀ» Á¦½ÃÇÑ´Ù. ½ÃÇè ½Ã¼³ÀÇ ¼º´É Á¶°ÇÀ»
Á¤ÇÏ¸ç ½ÃÇè ´ë»ó ¼³ºñ¸¦ ¼³Ä¡ÇÏ°í ½ÃÇèÇϱâ À§ÇÑ ±¸¼º ¿ä°Ç°ú ½ÃÇè ¼öÇà ÀýÂ÷¸¦ ±â¼úÇÑ´Ù.
°¡Áø ½ÃÇè Àü°ú ½ÃÇè Áß, ½ÃÇè ÈÄ¿¡ ÀûÇÕ¼º ÆÇÁ¤À» À§ÇÏ¿© °Ë»çÇÏ¿©¾ß ÇÒ »çÇ×µéÀ» Á¤Çϸç ÃÖ
Á¾ ÆÇÁ¤ Á¶°Ç ¹× ±âÁØ°ú ½ÃÇè °á°ú¿¡ ´ëÇÑ ¹®¼­È­ ó¸® ¹æ¹ýÀ» ±â¼úÇÏ°í ÀÖ´Ù.
¿µ¹®³»¿ë¿ä¾à First of all, corresponding telecommunication facilities to which a seismic design will
be applied in their installations against earthquake are classified in this standard. A
required response spectrum and a test response spectrum are defined as they are
essential techniques in conformance testing methods verifiying seismic design. This
standard defines performance conditions of testing machinary. And it describes test
composing elements to be constructed and a procedure. It also specifies inspection
items during, before and after a test to decide a conformity. It provides final decision
requirements and performance criteria and a documentation method about a test result.