Ç¥ÁØÈ­ Âü¿©¾È³»

TTAÀÇ Ç¥ÁØÇöȲ

Ȩ > Ç¥ÁØÈ­ °³¿ä > TTAÀÇ Ç¥ÁØÇöȲ

Ç¥ÁعøÈ£ TTAK.KO-06.0269/R1 ±¸Ç¥ÁعøÈ£
Á¦°³Á¤ÀÏ 2013-12-18 ÃÑÆäÀÌÁö 30
ÇѱÛÇ¥Áظí ÀüÀÚÆÄ ÀÎü ÃÑ ³ëÃâ·® ÃøÁ¤ ¹æ¹ý
¿µ¹®Ç¥Áظí Measurement Method of Total Human Exposure Levels to EMF
Çѱ۳»¿ë¿ä¾à º» Ç¥ÁØÀº ÀÏ»ó»ýÈ° ȯ°æ ÁÖº¯ÀÇ ÀüÀÚÆÄ ÃÑ ³ëÃâ·®À» Æò°¡Çϱâ À§ÇÑ ÃøÁ¤ ÀýÂ÷·Î 100 kHz ~ 3 GHz ÁÖÆļö ´ë¿ªÀÇ ¸ðµç ÀüÀÚÆÄ ¹ß»ý¿øÀ» ´ë»óÀ¸·Î ÇÑ´Ù. ¡®±¹¸³ÀüÆÄ¿¬±¸¿ø °í½Ã Á¦2010-46È£¡¯¿¡¼­ ±ÔÁ¤ÇÏ´Â ÀüÀÚÆÄ °­µµ ±âÁØÀÇ ÀûÇÕ¼º Æò°¡ ¹æ¹ýÀº Àû¿ë ¹üÀ§°¡ ¸Å¿ì ±¤¹üÀ§ÇÏ°í ÃøÁ¤ ¹æ¹ý ¹× ÀýÂ÷¸¦ Æ÷°ýÀûÀ¸·Î ±â¼úÇÏ°í ÀÖÀ¸¸ç, ±â Á¦Á¤ Ç¥ÁØÀÎ ¡®TTAK.KO-06.0125/R1¡¯Àº ±âÁö±¹¿¡¼­ º¹»çµÇ´Â ÀüÀÚÆÄ¿¡ ÀÇÇÑ ÀÎü ³ëÃâ·® ȤÀº ƯÁ¤ ½ÅÈ£¿ø¿¡ ÀÇÇÑ ÀüÀÚÆÄ °­µµ ÃøÁ¤¤ýÆò°¡¿¡ ´ëÇÑ ³»¿ë¸¸À» ´Ù·ç°í ÀÖ´Ù. µû¶ó¼­, º» Ç¥ÁØ¿¡¼­´Â ÀüÀÚÆÄ ÃÑ ³ëÃâ·® ÃøÁ¤ ±â±âÀÇ ±âÁØ, ÃøÁ¤ ÁöÁ¡ ¼±Á¤ ¹æ¹ý ¹× ÃøÁ¤ ÀýÂ÷ µî ÇöÇà °í½Ã ¹× ±â Á¦Á¤ Ç¥ÁØÀÇ ³»¿ëÀ» ¼öÁ¤¤ýº¸¿ÏÇÏ°í À̸¦ ´õ¿í ±¸Ã¼ÀûÀ¸·Î ±â¼úÇÏ¿´´Ù.
¿µ¹®³»¿ë¿ä¾à This standard is a procedure applicable to the RF total exposure around daily life environment(100 kHz ~ 3 GHz). The scope of RRA notice 2010-46 covers a wide frequency range and TTAK.KO-06.0125/R1 covers only human exposure levels of base stations or specific radio sources. Thus, This standard describes RRA notice more specifically and supplement the equipments requirement, selection of measurement position, measurement procedure and so on.
±¹Á¦Ç¥ÁØ
°ü·ÃÆÄÀÏ TTAK.KO-06.0269R1.pdf TTAK.KO-06.0269R1.pdf            

ÀÌÀü
ÃË°¢»óÈ£ÀÛ¿ë ¸ÞŸ µ¥ÀÌÅÍ
´ÙÀ½
64ºñÆ® ºí·Ï¾ÏÈ£ HIGHT