Ȩ > Ç¥ÁØÈ °³¿ä > TTAÀÇ Ç¥ÁØÇöȲ
Ç¥ÁعøÈ£ | TTAK.KO-04.0174-part1 | ±¸Ç¥ÁعøÈ£ | |
---|---|---|---|
Á¦°³Á¤ÀÏ | 2013-12-18 | ÃÑÆäÀÌÁö | 186 |
ÇѱÛÇ¥Áظí | Áö´ÉÇü Ȩ³×Æ®¿öÅ©¿ë ´ÜÁö¼¹ö ÇÁ·ÎÅäÄÝ ½ÃÇè ÀýÂ÷-Á¦1ºÎ: º£À̽º ÇÁ·ÎÅäÄÝ | ||
¿µ¹®Ç¥Áظí | The Complex Server Protocol Test Procedure for Intelligent Home Network - Part1 : Base Protocol | ||
Çѱ۳»¿ë¿ä¾à | ¡®Áö´ÉÇü Ȩ³×Æ®¿öÅ©¿ë ´ÜÁö ¼¹ö ÇÁ·ÎÅäÄÝ¡¯(KS X 4505) Ç¥ÁØÀº ´ÜÁö ³×Æ®¿öÅ© ȯ°æ¿¡¼ ´ÜÁö ¼¹ö¿Í Ȩ°ÔÀÌÆ®¿þÀÌ/¿ùÆеå, ÁÖÂ÷°üÁ¦ ½Ã½ºÅÛ, ¿¤¸®º£ÀÌÅÍ, CCTV, ¹«ÀÎ Åùè½Ã½ºÅÛ, ÁÖµ¿ ÃâÀÔ ÀåÄ¡, ¿ø°Ý °Ëħ±â¿Í °°Àº °ø¿ë ÀåÄ¡µé °£ ¸Þ½ÃÁö ¼Û¼ö½ÅÀ» À§ÇÑ ÇÁ·ÎÅäÄÝ ¹× ÇÁ·ÎÆÄÀÏÀ» Á¤ÀÇÇÏ°í ÀÖ´Ù. ¡®KS X 4505¡¯ Ç¥ÁØÀº Å©°Ô 4°³ÀÇ ÆÄÆ®·Î ±¸¼ºµÇ¾î ÀÖÀ¸¸ç, ¼¼ºÎÀûÀ¸·Î ¡®KS X 4505-1¡¯¿¡¼´Â ¸Þ½ÃÁö ¼Û¼ö½ÅÀ» ´ã´çÇÏ´Â º£À̽º ÇÁ·ÎÅäÄÝ¿¡ ´ëÇØ Á¤ÀÇÇÏ°í ÀÖ°í, ¡®KS X 4505-2¡¯, ¡®KS X 4505-3¡¯, ¡®KS X 4505-4¡¯¿¡¼´Â °¢ ÀåÄ¡º°·Î »ç¿ëÇÏ´Â ¸Þ½ÃÁö ÇÁ·ÎÆÄÀϵéÀ» Á¤ÀÇÇÏ°í ÀÖ´Ù. Áï ¡®KS X 4505-2¡¯, ¡®KS X 4505-3¡¯, ¡®KS X 4505-4¡¯¿¡¼ °¢ °ø¿ë ÀåÄ¡º°·Î Á¤ÀÇµÈ ¸Þ½ÃÁöµéÀ» ¡®KS X 4505-1¡¯¿¡¼ Á¤ÀÇÇÑ ¼Û¼ö½Å ÇÁ·ÎÅäÄÝ¿¡ ½Ç¾î »ó´ë ÀåÄ¡¿¡ Àü´ÞÇÏ¿© ´Ù¾çÇÑ ´ÜÁö ³×Æ®¿öÅ© ¼ºñ½º¸¦ Á¦°øÇÒ ¼ö ÀÖ°Ô µÈ´Ù. »ó±â ±â¼úÇÑ ¡®KS X 4505¡¯ Ç¥ÁØ¿¡ ´ëÇÑ ½ÃÇèÀº ¾Æ·¡¿Í °°ÀÌ Å©°Ô 2°¡Áö·Î ±¸ºÐÇÒ ¼ö ÀÖ´Ù.
1) ¸Þ½ÃÁö ¼Û¼ö½ÅÀ» ´ã´çÇÏ´Â º£À̽º ÇÁ·ÎÅäÄÝÀÇ ¸Þ½ÃÁö ÀûÇÕ¼º ½ÃÇè 2) ÀåÄ¡º° ¸Þ½ÃÁö(ÀåÄ¡ ÇÁ·ÎÆÄÀÏ)¿¡ µû¸¥ ÇÁ·ÎÆÄÀÏ ÀûÇÕ¼º ½ÃÇè ¹× ±â´É ½ÃÇè ù¹ø° ½ÃÇè¿¡¼´Â ±¸ÇöÇÑ ÀåÄ¡°¡ ¡®KS X 4505-1¡¯ º£À̽º ÇÁ·ÎÅäÄÝ ±â¹ÝÀ¸·Î Á¤»óÀûÀ¸·Î µ¿ÀÛÇÏ´ÂÁö¿¡ ´ëÇÑ °ËÁõÀ» ¼öÇàÇÏ°í, µÎ ¹ø° ½ÃÇè¿¡¼´Â ÀåÄ¡ Á¦¾î¿Í °°Àº ½ÇÁ¦ ¸Þ½ÃÁö¸¦ Àü´ÞÇßÀ» ¶§ ±× ±â´ÉÀÌ Á¤»óÀûÀ¸·Î ¼öÇàµÇ´ÂÁö¸¦ °ËÁõÇÏ°Ô µÈ´Ù. º» Ç¥ÁØ¿¡¼´Â ù¹ø° ½ÃÇèÀÎ º£À̽º ÇÁ·ÎÅäÄÝÀÇ ¸Þ½ÃÁö ÀûÇÕ¼º ½ÃÇè¿¡ ´ëÇØ ±â¼úÇÑ´Ù. |
||
¿µ¹®³»¿ë¿ä¾à | A specification of KS X 4505(The Complex Server Protocol for Intelligent Home Network) defines protocol and profiles for message exchange among shared units such as complex server, home gateway/wallpad, elevator, CCTV, remote meter reading and etc. KS X 4505 standard can be divided into 4 parts. KS X 4505 part 1 defines a base protocol which performs the massage delivery; KS X 4505 part 2, 3, 4 defines message profiles for each shared unit. A test for the KS X 4505 standard can be distinguished as follows;
1. A conformance test for messages of KS X 4505-1 base protocol 2. A conformance and functional test for device functions according to each profile of shared units In the first test, a verification of IUT (Implementation Under Test) is performed whether the IUT is working properly based on the KS X 4505-1 base protocol. In the second test, a verification of IUT is performed whether the IUT is working properly based on the KS X 4505-2, 3, 4 message profiles. In this standard, a test procedure for the first test is described. |
||
±¹Á¦Ç¥ÁØ | |||
°ü·ÃÆÄÀÏ | TTAK.KO-04.0174-part1.pdf |