ÇѱÛÇ¥Áظí Áö´ÉÇü Ȩ³×Æ®¿öÅ©¿ë ´ÜÁö¼­¹ö ÇÁ·ÎÅäÄÝ ½ÃÇè ÀýÂ÷-Á¦3ºÎ: ´ÜÁö°ø¿ëºÎ ÇÁ·ÎÆÄÀÏ
¿µ¹®Ç¥Áظí The Complex Server Protocol Test Procedure for Intelligent Home Network - Part3:Profile for Shared Unit in Complex Network
Çѱ۳»¿ë¿ä¾à ¡®Áö´ÉÇü Ȩ³×Æ®¿öÅ©¿ë ´ÜÁö ¼­¹ö ÇÁ·ÎÅäÄÝ¡¯(KS X 4505) Ç¥ÁØÀº ´ÜÁö ³×Æ®¿öÅ© ȯ°æ¿¡¼­ ´ÜÁö ¼­¹ö¿Í Ȩ°ÔÀÌÆ®¿þÀÌ/¿ùÆеå, ÁÖÂ÷°üÁ¦ ½Ã½ºÅÛ, ¿¤¸®º£ÀÌÅÍ, CCTV, ¹«ÀÎ ÅÃ¹è ½Ã½ºÅÛ, ÁÖµ¿ ÃâÀÔ ÀåÄ¡, ¿ø°Ý °Ëħ±â¿Í °°Àº °ø¿ë ÀåÄ¡µé °£ ¸Þ½ÃÁö ¼Û¼ö½ÅÀ» À§ÇÑ ÇÁ·ÎÅäÄÝ ¹× ÇÁ·ÎÆÄÀÏÀ» Á¤ÀÇÇÏ°í ÀÖ´Ù. KS X 4505 Ç¥ÁØÀº Å©°Ô 4°³ÀÇ ÆÄÆ®·Î ±¸¼ºµÇ¾î ÀÖÀ¸¸ç, ¼¼ºÎÀûÀ¸·Î ¡®KS X 4505-1¡¯¿¡¼­´Â ¸Þ½ÃÁö ¼Û¼ö½ÅÀ» ´ã´çÇÏ´Â º£À̽º ÇÁ·ÎÅäÄÝ¿¡ ´ëÇØ Á¤ÀÇÇÏ°í ÀÖ°í, 4505-2, 3, 4¿¡¼­´Â °¢ ÀåÄ¡ º°·Î »ç¿ëÇÏ´Â ¸Þ½ÃÁö ÇÁ·ÎÆÄÀϵéÀ» Á¤ÀÇÇÏ°í ÀÖ´Ù. Áï KS X 4505-2, 3, 4¿¡¼­ °¢ °ø¿ëÀåÄ¡ º°·Î Á¤ÀÇµÈ ¸Þ½ÃÁöµéÀ» ¡®KS X 4505-1¡¯¿¡¼­ Á¤ÀÇÇÑ ¼Û¼ö½Å ÇÁ·ÎÅäÄÝ¿¡ ½Ç¾î »ó´ë ÀåÄ¡¿¡ Àü´ÞÇÏ¿© ´Ù¾çÇÑ ´ÜÁö³×Æ®¿öÅ© ¼­ºñ½º¸¦ Á¦°øÇÒ ¼ö ÀÖ°Ô µÈ´Ù. »ó±â ±â¼úÇÑ¡¯KS X 4505¡¯ Ç¥ÁØ¿¡ ´ëÇÑ ½ÃÇèÀº ¾Æ·¡¿Í °°ÀÌ Å©°Ô 2°¡Áö·Î ±¸ºÐÇÒ ¼ö ÀÖ´Ù.

(1) ¸Þ½ÃÁö ¼Û¼ö½ÅÀ» ´ã´çÇÏ´Â º£À̽º ÇÁ·ÎÅäÄÝÀÇ ¸Þ½ÃÁö ÀûÇÕ¼º ½ÃÇè
(2) ÀåÄ¡º° ¸Þ½ÃÁö(ÀåÄ¡ ÇÁ·ÎÆÄÀÏ)¿¡ µû¸¥ ÇÁ·ÎÆÄÀÏ ÀûÇÕ¼º ½ÃÇè ¹× ±â´É ½ÃÇè

ù ¹ø° ½ÃÇè¿¡¼­´Â ±¸ÇöÇÑ ÀåÄ¡°¡ ¡®KS X 4505-1¡¯ º£À̽º ÇÁ·ÎÅäÄÝ ±â¹ÝÀ¸·Î Á¤»óÀûÀ¸·Î µ¿ÀÛÇÏ´ÂÁö¿¡ ´ëÇÑ °ËÁõÀ» ¼öÇàÇÏ°í, µÎ ¹ø° ½ÃÇè¿¡¼­´Â ÀåÄ¡ Á¦¾î¿Í °°Àº ½ÇÁ¦ ¸Þ½ÃÁö¸¦ Àü´Þ ÇßÀ» ¶§ ±× ±â´ÉÀÌ Á¤»óÀûÀ¸·Î ¼öÇàµÇ´ÂÁö¸¦ °ËÁõÇÏ°Ô µÈ´Ù. º» Ç¥ÁØ¿¡¼­´Â µÎ ¹ø° ½ÃÇè¿¡ ´ëÇØ ±â¼úÇÑ´Ù.
¿µ¹®³»¿ë¿ä¾à A specification of KS X 4505(The Complex Server Protocol for Intelligent Home Network) defines protocol and profiles for message exchange among shared units such as complex server, home gateway/wallpad, elevator, CCTV, remote meter reading and etc. KS X 4505 stadard can be divided into 4 parts. KS X 4505 part 1 defines a base protocol which performs the massage delivery; KS X 4505 part 2, 3, 4 defines message profiles for each shared unit. A test for the KS X 4505 standard can be distinguished as follows;

(1) A conformance test for messages of KS X 4505-1 base protocol
(2) A conformance and functional test for device functions according to each profile of shared units

In the first test, a verification of IUT (Implementation Under Test) is performed whether the IUT is working properly based on the KS X 4505-1 base protocol. In the second test, a verification of IUT is performed whether the IUT is working properly based on the KS X 4505-2, 3, 4 message profiles. In this standard, a test procedure for the second test is described.