Çѱ۳»¿ë¿ä¾à º» Ç¥ÁØÀº 3G ½Ã½ºÅÛµéÀÇ Åë½Å°ü¸®(TM; Telecommunication Management)¿¡ ÇÊ¿äÇÑ ¿ä±¸ »çÇ×°ú ¸ðµ¨À» ¼³¸íÇÑ´Ù
º» Ç¥ÁØÀº NE, EM, NM¿¡ Àû¿ëµÇ´Â 3G Àå¾Ö °ü¸®ÀÇ Àü¹ÝÀûÀÎ ¿ä±¸»çÇ×À» ±ÔÁ¤ÇÑ °ÍÀ¸·Î IMT-2000 ³×Æ®¿÷ÀÇ Àå¾Ö °ËÃâ/º¹±¸/¿¹Ãø¿¡ ´ëÇÑ ±âÁØÀ¸·Î »ç¿ëÇÒ ¼ö ÀÖ´Ù
º» Ç¥ÁØÀº NE(Network Element, e.g.RNC), EM(Element Manager)°ú NM(Network Manager)¿¡ Àû¿ëµÇ¾îÁö´Â 3¼¼´ë Àå¾Ö °ü¸®¿¡ ´ëÇÑ Àü¹ÝÀûÀÎ ¿ä±¸»çÇ×À» »ó¼úÇÑ´Ù.
4Àý°ú 5ÀýÀº 3G ½Ã½ºÅÛ¿¡¼­ÀÇ ¾Ë¶÷, ¿î¿µ »óÅ µ¥ÀÌÅÍ, Å×½ºÆ® °á°úÀÇ »ý¼º, ¼öÁý, Ç¥Çö¿¡ ´ëÇÑ, ±×¸®°í Àå¾Ö °ËÃâ¿¡ ´ëÇÑ Àå¾Ö °ü¸® °³³ä°ú ±â´É ¿ä±¸»çÇ×À» Á¤ÀÇÇÑ´Ù.
¼­·Î ´Ù¸¥ ¿©·¯ ÆǸž÷ÀÚµéÀÇ Àåºñ°£¿¡ ÀÌ·¯ÇÑ ±â´ÉµéÀÇ Çü½ÄÀûÀΠǥÁØÀÌ ÇÊ¿äÇÏÁö´Â ¾Ê±â ¶§¹®¿¡ ÀÌ·¯ÇÑ ±â´ÉµéÀº ºñÇü½ÄÀûÀ¸·Î ±â¼úµÈ´Ù.
ÀÌ Àýµé¿¡¼­ ´Ù·ç¾î Áö´Â ±â´É ¿µ¿ªÀº ´ÙÀ½°ú °°´Ù.
1) NE¿¡¼­ÀÇ Àå¾Ö °¨½Ã¿Í °ËÃâ
2) ¾Ë¶÷(¾Ë¶÷ ÁßÁö Æ÷ÇÔ)°ú ¿î¿µ»óÀÇ »óÅ º¯È­ÀÇ Å뺸
3) NE·ÎºÎÅÍÀÇ ÇöÀç ¾Ë¶÷ÀÇ °Ë»ö
4) NE¿¡¼­ÀÇ Àå¾Ö °Ý¸®¿Í ¹æ¾î ¸ÞÄ¿´ÏÁò
5) ¾Ë¶÷ ÇÊÅ͸µ
6) ¾Ë¶÷ Á¤µµ ·¹º§(severity level)ÀÇ °ü¸®
7) OS¿¡¼­ÀÇ ¾Ë¶÷°ú ¿î¿µ»óÀÇ »óÅ µ¥ÀÌ
¿µ¹®³»¿ë¿ä¾à The present document specifies the overall requirements for 3G Fault Management (FM) as it applies to the Network Elements (NE), Element Manger (EM) and Network Manager (NM).
Clause 4 defines the FM concept and functional requirements for the detection of faults and the generation, collection and presentation of alarms, operational state data and test results across 3G systems. These functions are described on a non-formal level since the formal standardisation of these functions across the different vendors' equipment is not required. The functional areas specified in the present document cover:
? fault surveillance and detection in the NEs;
? notification of alarms (including alarm cease) and operational state changes;
? retrieval of current alarms from the NEs;
? fault isolation and defence mechanisms in the NEs;
? alarm filtering;
? management of alarm severity levels;
? alarm and operational state data presentation and analysis at the Operations System (OS);